Our products

  • Setter Inline

    Balancing valve for VVC, heating, refrigeration, etc. SETTER In-line with direct readable flow makes it possible to optimize the system and thereby reduce energy costs without using expensive instruments. The valve is available in several flow rates from 0.6 l / min up to 40 l / min.

    Data sheet

  • Setter Rondo

    Direct hydraulic balancing and control of flows to consumers. SETTER Rondo balancing valves offer a quick, easy and accurate method of adjusting the flow rates through heating, ventilation, air conditioning and cooling systems.

    Data sheet

  • Setter Bypass

    Direct hydraulic balancing and control of flows to consumers or in a subsystem SETTER Bypass balancing valves offer an easy and accurate method of adjusting the flow rates for heating-, ventilation-, air conditioning - and cooling systems. The solar type is designed for higher operating temperatures.

    Data sheet

  • Flometer

    The required flow rate can be set directly in each heating and air-conditioning circuit. The display of the flow rate allows a precise and easy reading without expensive commissioning equipment.

    Data sheet

  • FlowControl Dynamic

    The E-Just automatic flow rate cartridges ensure that the designated flow rate will not be exceeded regardless of pressure fluctuations in the system. By means of a special designed key each cartridge can be easily adjusted to one of 39 different flow rates.

    Data sheet

  • Nicab Compact

    The COMPACT range of 2 and 3 way motorised ball valves are designed for use in secondary refrigerant systems (both HT and LT temperature i.e. -15° C to -35° C). The ball in the 3-way diverting valve is specifically designed to ensure constant flow when the valve changes position i.e. when defrosting.

    Data sheet Electrical scheme

  • Nicab DUE

    The Nicab Due ballvalve for secondary refrigerant systems is a development from the Nicab STANDARD, specially designed to handle low temperatures and different types of secondary refrigerants like Glycol, Freezium, Hy-Cool, Temper and Tyfoxit.

    Data sheet Electrical scheme

  • Nicab Maxi

    Nicab Maxi is a motorised ballvalve for control of secondary refrigerant systems. The valve function is ON/OFF and is compatible with most secondary refrigerants including Glycol, Freezium, Hy-Cool, Temper and Tyfoxit.

    Data sheet Electrical scheme

  • Nicab Flex

    Nicab Flex is a butterfly valve suitable for continous control of brine, water, air and low-pressure steam (up to 110 ° C) or for use as a shut-off valve. The valve is combined with an electric actuator, 230V (standard) or 24V (option).

    Data sheet Electrical scheme

  • Nicab Optimal Insulating box

    Nicab Optimal is an insulating box for the FlowControl ballvalvser Nicab Compact & Nicab DUE. The box protects the valve from ice and prevents problems with condensation.

    Data sheet

  • Nicab Exact

    The new ballvalve with technology: Perfect for a wide range of applications. The new 2- and 3-way ballvalves, in DZR (dezincification-resistant) brass, are the ideal combination in conjunction with the new rotary drives and damper drives with spring return as option.

    Data sheet Electrical scheme

  • VUN/BUN

    Silicone free control valve for continuous control of cold water, hot water or air in closed networks. Water quality as per VDI 2035. The valve is used together with actuators AVM115S, AVM321S and AVM322S.

    Data sheet Electrical scheme

  • VQE/BQE

    These valves are used for continuous control of secondary refrigerants, cold and hot water in closed networks. Water quality as per VDI 2035. Together with actuators AVM321S, AVM322S, AVM 234S and AVF 234S the valve works as a regulating unit.

    Data sheet Electrical scheme

  • Valves On/Off

    Open

  • Valves Regulating

    Open